Cart

  • Cart Empty!
Smart UPS 700va W/auto Select Input Voltage 120v/230v In 120v Out

Smart UPS 700va W/auto Select Input Voltage 120v/230v In 120v Out

 Without VATWith VAT
Base Price:€874,77€1.058,48
Recupel:+ €0,12+ €0,15
BeBat:+ €0,05+ €0,06
Total:€874,94€1.058,68
Part Number: SU700X167
Language: UK
Real time Stock Check

Introduction

APC Smart-UPS 700VA w/Auto Select Input Voltage 120V/230V In 120V Out APC Smart-UPS, 700VA/450W, Input 120V, 230V/Output 120V, Interface Port DB-9 RS-232, SmartSlot

Features

  • Adjustable voltage sensitivity
  • Adjustable voltage-transfer points
  • Audible alarms
  • Automatic restart of loads after UPS shutdown
  • Automatic self-test
  • Boost and Trim Automatic Voltage Regulation (AVR)
  • Cold-start capable
  • Disconnected battery notification
  • Front-access servicing
  • Generator compatible
  • Hot-swappable batteries
  • InfraStruXure Manager compatible
  • Intelligent battery management
  • LED status indicators
  • Network manageable
  • Power conditioning
  • Predictive failure notification
  • Resettable circuit breakers
  • Safety-agency approved
  • Serial Connectivity
  • SmartSlot
  • Temperature-compensated battery charging
  • User-replaceable batteries

Specifications


Output
Output Power Capacity  450 Watts / 700 VA
Max Configurable Power  450 Watts / 700 VA
Nominal Output Voltage  120V
Output Voltage Distortion  Less than 5% at full load
Output Frequency (sync to mains)  47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Crest Factor  up to 5 : 1
Waveform Type  Sine wave
Output Connections  (6) NEMA 5-15R
Input
Nominal Input Voltage  120V,230V
Input Frequency  50/60 Hz +/- 3 Hz (auto sensing)
Input Connections  British BS1363A

 Italian CEI 23-16

 NEMA 5-15P

 Schuko CEE 7/7P

Cord Length  6 feet ( 1.83 meters)
Input voltage range for main operations  187 - 242 (220V),92 - 147V
Input voltage adjustable range for mains operation  --V
Batteries & Runtime
Battery Type  Maintenance-free sealed Lead-Acid battery with suspended electrolyte :  leakproof
Typical recharge time  3 hour(s)
Replacement battery cartridge  CURK6, RBC6
RBC Quantity  1
Typical Backup Time
at Half Load
 40.9 minutes (225 Watts)
Typical Backup Time
at Full Load
 12.5 minutes (450 Watts)
Runtime Chart  Smart-UPS
Communications & Management
Interface Port(s)  DB-9 RS-232,SmartSlot
Available SmartSlot Interface Quantity  1
Control panel  LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : and Overload Indicators
Audible Alarm  Alarm when on battery : distinctive low battery alarm : configurable  delays
Emergency Power Off (EPO)  Optional
Surge Protection and Filtering
Surge energy rating  480 Joules
Filtering  Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Physical
Maximum Height  8.50 inches (216 mm)
Maximum Width  6.70 inches (170 mm)
Maximum depth  17.30 inches (439 mm)
Net Weight  53.00 lbs. ( 24.09 kg)
Color  Beige
Environmental
Operating Environment  0 - 40 °C (32 - 104 °F)
Operating Relative Humidity  0 - 95%
Operating Elevation  0-10000 feet (0-3000 meters)
Storage Temperature  -15 - 45 °C (5 - 113 °F)
Storage Relative Humidity  0 - 95%
Storage Elevation  0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit  45 dBA
Online Thermal Dissipation  135 BTU/hr
Protection Class  --
.